Product characteristics:

Specification BR-20 150 1P BR-20 275 1P BR-20 320 1P BR-20 385 1P BR-20 440 1P
SPD classification according to EN61643-11 Type 2 Type 2 Type 2 Type 2 Type 2
SPD classification according to IEC61643-11 Class II Class II Class II Class II Class II
Max. continuous operating a.c. voltage Uc 150V 275V 320V 385V 440V
Nominal discharge current (8/20μs) In 10kA 10kA 10kA 10kA 10kA
Max. discharge current (8/20μs) Imax 20kA 20kA 20kA 20kA 20kA
Voltage protection level Up ≤0.8kV ≤1.3kV ≤1.5kV ≤1.8kV ≤2.0kV
Voltage protection level 5kA Up ≤0.6kV ≤1kV ≤1.2kV ≤1.4kV ≤1.6kV
Max. backup fuse 63A gG 63A gG 63A gG 63A gG 63A gG
Short-circuit withstand capacity Isccr 25kA 25kA 25kA 25kA 25kA
Temporary overvoltage TOV-withstand UT 175V/5sec. 335V/5sec. 350V/5sec. 550V/5sec. 580V/5sec.
Temporary overvoltage TOV-safe failure UT 250V/120min. 440V/120min. 550V/120min. 660V/120min. 770V/120min.
Response time tA ≤25ns ≤25ns ≤25ns ≤25ns ≤25ns
Operating temperature range Tu -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red green/red green/red
Cross-section area (Min.) 4mm² 4mm² 4mm² 4mm² 4mm²
Cross-section area (Max.) 35mm² 35mm² 35mm² 35mm² 35mm²
For mounting on 35mm Din rail
Enclosure material Thermoplastic   UL94-V0
Degree of protection IP20 IP20 IP20 IP20 IP20
Order Code B18731 B18733 B18735 B18737 B18739
Order Code (With remote signaling) B18732 B18734 B18736 B18738 B18740

Features:

• Low price surge protection device (SPD), Type 2 or Class II test level, selectable in nominal discharge current 10kA with max. discharge current of 20kA accordingly.

• Surge Protection Device for transient electrical over-voltages.

• DIN rail mounting, easy installation, compact size, and good performance.

• Class 2 SPD for typical waveforms of 8/20 μs.

• Best surge protector for your power supply system with rated voltage of 400V AC 50Hz/60Hz.

• The SPD is designed in accordance with IEC Class II.

Application:

• They ensure protection against overvoltage conditions.

• For the protection of low voltage distribution systems against direct lightning strike into the overhead power supply line or external lightning protection system (IEC 62305).

• They are suitable for installation in secondary boards and in terminal equipment.

Installation:

• The line of surge arresters includes a full range of compact protectors for installation on DIN rail

• When the fault indication window turns from green to red please replace the cartridge as soon as possible

• After the installation is complete, check that the protection unit is plug in place, close the automatic circuit breaker (fuse) switch, check the working status is normal.

WE ARE HERE TO SUPPORT YOU!

Further information or a personal consultation? Our products and know-how are there to provide solutions.

RELATED PRODUCTS
RELATED NEWS
YOU MAY ALSO WANT TO SEE
GET SURGE PROTECTION
SOLUTIONSTODAY!
icon
icon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.