...

BR-20 1+1 Type 2 20kA Surge Protective Device For TT And TNS

Get A Quote
Description

Product characteristics:

Specification BR-20 150 1+1 BR-20 275 1+1 BR-20 320 1+1 BR-20 385 1+1 BR-20 440 1+1
SPD classification according to EN61643-11 Type 2 Type 2 Type 2 Type 2 Type 2
SPD classification according to IEC61643-11 Class II Class II Class II Class II Class II
Max. continuous operating a.c. voltage(L-N) Uc 150V 275V 320V 385V 440V
Max. continuous operating a.c. voltage(N-PE) Uc 255V 255V 255V 255V 255V
Nominal discharge current (8/20μs) In 10kA 10kA 10kA 10kA 10kA
Max. discharge current (8/20μs) Imax 20kA 20kA 20kA 20kA 20kA
Voltage protection level (L-N) Up ≤0.8kV ≤1.3kV ≤1.5kV ≤1.8kV ≤2.0kV
Voltage protection level 5kA (L-N) Up ≤0.6kV ≤1kV ≤1.2kV ≤1.4kV ≤1.6kV
Voltage protection level (N-PE) Up ≤1.5kV ≤1.5kV ≤1.5kV ≤1.5kV ≤1.5kV
Max. backup fuse 63A gG 63A gG 63A gG 63A gG 63A gG
Short-circuit withstand capacity Isccr 25kA 25kA 25kA 25kA 25kA
Temporary overvoltage TOV-withstand (L-N) UT 175V/5sec. 335V/5sec. 350V/5sec. 550V/5sec. 580V/5sec.
Temporary overvoltage TOV-safe failure(L-N) UT 250V/120min. 440V/120min. 550V/120min. 660V/120min. 770V/120min.
Temporary overvoltage TOV-withstand(N-PE) UT 1200V/200ms 1200V/200ms 1200V/200ms 1200V/200ms 1200V/200ms
Response time (L-N) tA ≤25ns ≤25ns ≤25ns ≤25ns ≤25ns
Response time (N-PE) tA ≤100ns ≤100ns ≤100ns ≤100ns ≤100ns
Operating temperature range Tu -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red green/red green/red
Cross-section area (Min.) 4mm² 4mm² 4mm² 4mm² 4mm²
Cross-section area (Max.) 35mm² 35mm² 35mm² 35mm² 35mm²
For mounting on 35mm Din rail
Enclosure material Thermoplastic   UL94-V0
Degree of protection IP20 IP20 IP20 IP20 IP20
Order Code B18751 B18753 B18755 B18757 B18759
Order Code (With remote signaling) B18752 B18754 B18756 B18758 B18760

Features:

20kA Class C for 3 Phase Supply.

It is compact devices designed to protect single-phase+neutral networks at the main switchboard.

The product is complying with the standards: EN 61643-11, CEI 61643-11, UL1449 ed. 4 compliance.

The protection circuitry is based on high energy varistor with thermal disconnection devices.

Easy to operate.

There is an indicator on the cartridges to signal failure mode.

Long service life.

The BR-20 is DIN rail mounted and features replaceable modules for the safest and easiest installation and maintenance.

Excellent functionality

Consistent plug ability(even for N/PE spark gap)

BR-20 series are designed to protect against lighting surge voltages. These units must be installed in parallel on the AC networks to be protected and provide common and differential modes protection.

Thermal disconnect device for each individual connector

Surge Protection Device / Arrester are for protection against switching surges.

With or without floating remote indication contact

Time of response<25ns.

The color of the visible window shows operating status, green means normal, red means abnormal.

Application:

These devices protect low-voltage consumer systems from over voltages of all types.

Protection of terminal devices.

For using in the zones concept at boundary 1-2.

Used for protection against electrical transients.

WE ARE HERE TO SUPPORT YOU!

Further information or a personal consultation? Our products and know-how are there to provide solutions.

RELATED PRODUCTS
RELATED NEWS
YOU MAY ALSO WANT TO SEE
GET SURGE PROTECTION
SOLUTIONSTODAY!
icon
icon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.