Product characteristics:

Specification BR-80 150 3P BR-80 275 3P BR-80 320 3P BR-80 385 3P
SPD classification according to EN61643-11 Type 2 Type 2 Type 2 Type 2
SPD classification according to IEC61643-11 Class II Class II Class II Class II
Max. continuous operating a.c. voltage Uc 150V 275V 320V 385V
Nominal discharge current (8/20μs) In 40kA 40kA 40kA 40kA
Max. discharge current (8/20μs) Imax 80kA 80kA 80kA 80kA
Voltage protection level Up ≤1.0kV ≤1.7kV ≤2.0kV ≤2.3kV
Voltage protection level 5kA Up ≤0.5kV ≤0.9kV ≤1.1kV ≤1.3kV
Max. backup fuse 200A gG 200A gG 200A gG 200A gG
Short-circuit withstand capacity Isccr 25kA 25kA 25kA 25kA
Temporary overvoltage TOV-withstand UT 175V/5sec. 335V/5sec. 350V/5sec. 550V/5sec.
Temporary overvoltage TOV-safe failure UT 250V/120min. 440V/120min. 550V/120min. 660V/120min.
Response time tA ≤25ns ≤25ns ≤25ns ≤25ns
Operating temperature range Tu -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red green/red
Cross-section area (Min.) 4mm² 4mm² 4mm² 4mm²
Cross-section area (Max.) 35mm² 35mm² 35mm² 35mm²
For mounting on 35mm Din rail
Enclosure material Thermoplastic   UL94-V0
Degree of protection IP20 IP20 IP20 IP20
Order Code B18268 B18270 B18272 B18274
Order Code (With remote signaling) B18269 B18271 B18273 B18275

Features:

Visual status display

Labeled connections

Type 2 (class II/C) for main boards, distribution boards and consumer units.

Available with and without remote signalling contacts.

1 pole up to 4 poles protected.

BR-80 consists of a high performance varistor block with thermal disconnection device. The plug-in module/base design facilitates replacement of a failed module in situ without the need to remove system wiring.

Solutions to meet IEC 61643-1 and EN 61643-11

Application:

Distribution switch board located downstream from a Type 1 Lightning Current Arrester.

Protecting them from direct and indirect lightning impulse and other transient overvoltage.

Protects low-voltage systems against overvoltage triggered by lightning strikes or grid switching operations.

Ideal for industrial applications.

At the origin of the electrical installation in the main switchboard, in areas where electromagnetic fields caused by lightning currents are dominant (excluding a direct strike).

Suitable for TN-C systems.

Preventing the spread of medium overvoltage (Up) in the electrical installation and protecting equipment that is connected to it.

WE ARE HERE TO SUPPORT YOU!

Further information or a personal consultation? Our products and know-how are there to provide solutions.

RELATED PRODUCTS
RELATED NEWS
YOU MAY ALSO WANT TO SEE
GET SURGE PROTECTION
SOLUTIONSTODAY!
icon
icon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.