...

BR-200 3+1 Type 2 200kA Surge Protective Device For TT And TNS

Get A Quote
Description

Product characteristics:

Specification BR-200 275 3+1 BR-200 320 3+1 BR-200 385 3+1
SPD classification according to EN61643-11 Type 2 Type 2 Type 2
SPD classification according to IEC61643-11 Class II Class II Class II
Max. continuous operating a.c. voltage(L-N) Uc 275V 320V 385V
Max. continuous operating a.c. voltage(N-PE) Uc 255V 255V 255V
Nominal discharge current (8/20μs) In 100kA 100kA 100kA
Max. discharge current (8/20μs) Imax 200kA 200kA 200kA
Voltage protection level (L-N) Up ≤1.9kV ≤2.1kV ≤2.5kV
Voltage protection level 5kA (L-N) Up ≤0.6kV ≤1.0kV ≤1.2kV
Voltage protection level (N-PE) Up ≤1.5kV ≤1.5kV ≤1.5kV
Max. backup fuse 350A gG 350A gG 350A gG
Short-circuit withstand capacity Isccr 25kA 25kA 25kA
Temporary overvoltage TOV-withstand (L-N) UT 335V/5sec. 350V/5sec. 550V/5sec.
Temporary overvoltage TOV-safe failure(L-N) UT 440V/120min. 550V/120min. 660V/120min.
Temporary overvoltage TOV-withstand(N-PE) UT 1200V/200ms 1200V/200ms 1200V/200ms
Response time (L-N) tA ≤25ns ≤25ns ≤25ns
Response time (N-PE) tA ≤100ns ≤100ns ≤100ns
Operating temperature range Tu -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red
Cross-section area (Min.) 4mm² 4mm² 4mm²
Cross-section area (Max.) 35mm² 35mm² 35mm²
For mounting on 35mm Din rail
Enclosure material Thermoplastic   UL94-V0
Degree of protection IP20 IP20 IP20
Order Code B17442 B17444 B17446
Order Code (With remote signaling) B17443 B17445 B17447

Features:

1) Big discharger current capacity, low residual voltage, quick response

2) IP20, UL94 V0

3) Lowe leakage current and rate of change

4) Class II / Type 2 surge protective devices.

5) Heat isolation technique, no fire disaster

6) The core parts are metal oxide varistor components with high discharge capacity.

7) Apply special shock fuse pieces, with high reliability

8) Standard compliance: IEC61643-11, EN61643-11

9) With power indicator to display working condition

10) Protecting low voltage devices from surge for TN-S (or TT 3+1 mode as custom-made) power supply systems.

11) Temperature control protective circuit, built-in heat protection, automatic release unit

12) Mount on the 35mm DIN rail.

13) 3+1 protection model(L-N, N-PE), suitable for the poor power grid area

14) Nominal Discharge Current: 100kA

15) Max. Discharge Current: 200kA

16) Exquisite process, can work under the hostile environment for a long time, like acid, alkali, dust, salt fog, wet, etc.

Application:

1) Three phase power SPD is suitable for system power protection, such as switching room, power distribution cabinet, switch cabinet, AC distribution board, etc.

2) For using in the lightning protection zones concept at boundary 1-2.

3) Distribution box with outdoor input in the building and each floor

4) AC power line of house, bank, and telecom tower and so on.

5) AC power surge protective device is used in AC power supply system (50/60Hz) and low-voltage control system to protect from lightning striker and transient over-voltage.

6) Automation machine room, power supply panel of converting station main control room

WE ARE HERE TO SUPPORT YOU!

Further information or a personal consultation? Our products and know-how are there to provide solutions.

RELATED PRODUCTS
RELATED NEWS
YOU MAY ALSO WANT TO SEE
GET SURGE PROTECTION
SOLUTIONSTODAY!
icon
icon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.