BR-25GR 1+1 Type 1 25kA Surge Arrester For TT And TNS

Get A Quote
Description

Product characteristics:

Specification BR-25GR 150 1+1 BR-25GR 275 1+1 BR-25GR 320 1+1
SPD classification according to EN61643-11 Type 1 + Type 2 Type 1 + Type 2 Type 1 + Type 2
SPD classification according to IEC61643-11 Class I + Class II Class I + Class II Class I + Class II
Nominal operating voltage Un 120V(50/60Hz) 230V(50/60Hz) 250V(50/60Hz)
Max. continuous operating a.c. voltage Uc (L-N/N-PE) 150V/255V(50/60Hz) 275V/255V(50/60Hz) 320V/255V(50/60Hz)
Lightning impulse current (10/350μs) Iimp (L-N/N-PE) 25kA/50kA 25kA/50kA 25kA/50kA
Nominal discharge current (8/20μs) In (L-N/N-PE) 25kA/50kA 25kA/50kA 25kA/50kA
Max. discharge current (8/20μs) Imax (L-N/N-PE) 100kA/100kA 100kA/100kA 100kA/100kA
Quantity of electric charge (L-N, N-PE) Q 12.5As, 25As 12.5As, 25As 12.5As, 25As
Specific energy (L-N, N-PE) W/R 156kJ/Ω, 625kJ/Ω 156kJ/Ω, 625kJ/Ω 156kJ/Ω, 625kJ/Ω
Voltage protection level Up (L-N/N-PE) ≤2.3kV/≤1.5kV ≤2.3kV/≤1.5kV ≤2.3kV/≤1.5kV
Short-circuit current rating a.c. Isccr (L-N/N-PE) 25kA rms/100A rms 25kA rms/100A rms 25kA rms/100A rms
Max. backup fuse 315A gG 315A gG 315A gG
Temporary overvoltage TOV-withstand UT (L-N) 250V/120min. 440V/120min. 550V/120min.
Temporary overvoltage TOV-withstand UT (N-PE) 1200V/200ms 1200V/200ms 1200V/200ms
Response time tA ≤100ns ≤100ns ≤100ns
Operating temperature range Tu -40℃-80℃ -40℃-80℃ -40℃-80℃
Cross-section area (Min.) 4mm² 4mm² 4mm²
Cross-section area (Max.) 35mm² 35mm² 35mm²
For mounting on 35mm Din rail
Enclosure material Thermoplastic UL94-V0
Degree of protection IP20 IP20 IP20
Order Code B17130 B17143 B17156
Order Code (With remote signaling) B17131 B17144 B17157

Features:

• This is a kind of fine quality surge protecting device, fire proof and corrosion-resistant. Quickly react speed with strong bearing capacity.

• Simple and easy to use. More reliable and more safety.

• Working status indicating window, red means failure, which can effectively react the working status in time.

• Surge protect, prevents home electric network receive excessive impact while lightening.

• Detachable 35mm Din rail installation design.

Application:

• Protects electrical installations against direct lightning strokes, and discharge the back-current from lightning spreading from the earth conductor to the network conductors.

• Used to AC power system, power distribution system, terminal devices, electronic equipment, buildings, industrial enterprises and Medical institutes etc.

Installation:

Type 1 or Type 1+2 SPD (Iimp ≥ 12.5 kA) compulsory at the installation source (main distribution board in secondary buildings).

Installations more than 10 m high (apartment buildings, office buildings, hotels, etc.): type 2 SPD recommended for protecting private areas and floor distributors (communal areas) in addition to a type 1 or type 1+2 SPDs.

WE ARE HERE TO SUPPORT YOU!

Further information or a personal consultation? Our products and know-how are there to provide solutions.

RELATED PRODUCTS
RELATED NEWS
YOU MAY ALSO WANT TO SEE
GET SURGE PROTECTION
SOLUTIONSTODAY!
icon
icon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.