BR-50GR 3+1 Type 1 50kA Surge Arrester for TT and TNS

Get A Quote
Description

Product characteristics:

Specification BR-50GR 150 3+1 BR-50GR 275 3+1 BR-50GR 320 3+1
SPD classification according to EN61643-11 Type 1 + Type 2 Type 1 + Type 2 Type 1 + Type 2
SPD classification according to IEC61643-11 Class I + Class II Class I + Class II Class I + Class II
Nominal operating voltage Un 120V/240V(50/60Hz) 230V/400V(50/60Hz) 250V/440V(50/60Hz)
Max. continuous operating a.c. voltage Uc (L-N/N-PE) 150V/255V(50/60Hz) 275V/255V(50/60Hz) 320V/255V(50/60Hz)
Lightning impulse current (10/350μs) Iimp (L-N/N-PE) 50kA/100kA 50kA/100kA 50kA/100kA
Nominal discharge current (8/20μs) In (L-N/N-PE) 50kA/100kA 50kA/100kA 50kA/100kA
Max. discharge current (8/20μs) Imax (L-N/N-PE) 200kA/200kA 200kA/200kA 200kA/200kA
Quantity of electric charge (L-N, N-PE) Q 25As, 50As 25As, 50As 25As, 50As
Specific energy (L-N, N-PE) W/R 625kJ/Ω, 2500kJ/Ω 625kJ/Ω, 2500kJ/Ω 625kJ/Ω, 2500kJ/Ω
Voltage protection level Up (L-N/N-PE) ≤2.3kV/≤1.5kV ≤2.3kV/≤1.5kV ≤2.3kV/≤1.5kV
Short-circuit current rating a.c. Isccr (L-N/N-PE) 25kA rms/100A rms 25kA rms/100A rms 25kA rms/100A rms
Max. backup fuse 350A gG 350A gG 350A gG
Temporary overvoltage TOV-withstand UT (L-N) 250V/120min. 440V/120min. 550V/120min.
Temporary overvoltage TOV-withstand UT (N-PE) 1200V/200ms 1200V/200ms 1200V/200ms
Response time tA ≤100ns ≤100ns ≤100ns
Operating temperature range Tu -40℃-80℃ -40℃-80℃ -40℃-80℃
Cross-section area (Min.) 4mm² 4mm² 4mm²
Cross-section area (Max.) 35mm² 35mm² 35mm²
For mounting on 35mm Din rail
Enclosure material Thermoplastic UL94-V0
Degree of protection IP20 IP20 IP20
Order Code B17166 B18167 B17192
Order Code (With remote signaling) B17167 B18168 B17193

Features:

Endurable, sustains multiple strikes.

LED status indication.

Protection class: Type 1+2, Class I +Class II.

BR-50GR 3P+N is suitable for TT and TN-S system.

Application:

● Suitable for TT and TN-S system.

● Used in industrial systems and buildings with external lightning protection of Classes I to IV.

● For the protection of low voltage distribution systems against direct lightning strike into the overhead power supply line or external lightning protection system.

● Can be used in standard distributor housing.

● Used to protect all kinds of electrical equipment in the power system from lightning over-voltage, operation over-voltage, power frequency transient over-voltage impact damage to an electrical appliance.

WE ARE HERE TO SUPPORT YOU!

Further information or a personal consultation? Our products and know-how are there to provide solutions.

RELATED PRODUCTS
RELATED NEWS
YOU MAY ALSO WANT TO SEE
GET SURGE PROTECTION
SOLUTIONSTODAY!
icon
icon
Seraphinite AcceleratorOptimized by Seraphinite Accelerator
Turns on site high speed to be attractive for people and search engines.