BR-25GR 3P Type 1 25kA Surge Arrester for TN-C

Get A Quote
Description

Product characteristics:

Specification BR-25GR 150 3P BR-25GR 275 3P BR-25GR 320 3P
SPD classification according to EN61643-11 Type 1 + Type 2 Type 1 + Type 2 Type 1 + Type 2
SPD classification according to IEC61643-11 Class I + Class II Class I + Class II Class I + Class II
Nominal operating voltage Un 120V/240V(50/60Hz) 230V/400V(50/60Hz) 250V/440V(50/60Hz)
Max. continuous operating a.c. voltage Uc 150V(50/60Hz) 275V(50/60Hz) 320V(50/60Hz)
Lightning impulse current (10/350μs) Iimp 25kA 25kA 25kA
Nominal discharge current (8/20μs) In 25kA 25kA 25kA
Max. discharge current (8/20μs) Imax 100kA 100kA 100kA
Quantity of electric charge Q 12.5As 12.5As 12.5As
Specific energy W/R 156kJ/Ω 156kJ/Ω 156kJ/Ω
Voltage protection level Up ≤2.3kV ≤2.3kV ≤2.3kV
Short-circuit current rating a.c. Isccr 25kA rms 25kA rms 25kA rms
Max. backup fuse 315A gG 315A gG 315A gG
Temporary overvoltage TOV-withstand UT 250V/120min. 440V/120min. 550V/120min.
Response time tA ≤100ns ≤100ns ≤100ns
Operating temperature range Tu -40℃-80℃ -40℃-80℃ -40℃-80℃
Cross-section area (Min.) 4mm² 4mm² 4mm²
Cross-section area (Max.) 35mm² 35mm² 35mm²
For mounting on 35mm Din rail
Enclosure material Thermoplastic UL94-V0
Degree of protection IP20 IP20 IP20
Order Code B17122 B17135 B17148
Order Code (With remote signaling) B17123 B17136 B17149

Features:

Indicating window.

Designed according to IEC 61643-11.

A protective device that prevents lightning overvoltage and transient overcurrent from intruding into the power supply line from disrupting the normal operation of the power supply system and electrical equipment.

High performance varistor with thermal disconnection tripping device

Three-phase AC power surge arrester

Protection class: Type 1,Class I

Parallel surge protection device

Surge areeare used to guard sensitive equipments from voltage spike.

With high lightning current discharge capacity

Impact discharge current of single module reaches 25kA(10/350)

The Type 1 arresters combine high performance and user-friendliness in a single device. Their electrical parameters were rated for the most stringent requirements within lightning and surge protection systems.

Imax: 100KA(8/20)

Application:

• It is applicable to lightning protection for the power system in areas with high lightning risk (LPZ0B or the interface between LPZ0B and LPZ1).

• Suitable for three-phase TN-C power supply systems with AC of 50 to 60Hz

• Mainly used for TN-C power supply system (B) level overvoltage protection

• Generally installed in the building into the low-voltage main distribution cabinet or low-voltage main switch.

Installation:

It is installed in parallel in the main distribution inlet panel at the low-voltage entry end of transformer, the distribution box with overhead input in the building, the outdoor distribution cabinet/distribution box and other positions.