BR-30FU 3+1 30kA 3 Phase Type 2 SPD

Get A Quote
Description

Product characteristics:

Specification BR-30FU 150 3+1 BR-30FU 275 3+1 BR-30FU 320 3+1 BR-30FU 385 3+1 BR-30FU 440 3+1
SPD classification according to EN61643-11 Type 2 Type 2 Type 2 Type 2 Type 2
SPD classification according to IEC61643-11 Class II Class II Class II Class II Class II
Max. continuous operating a.c. voltage(L-N) Uc 150V 275V 320V 385V 440V
Max. continuous operating a.c. voltage(N-PE) Uc 255V 255V 255V 255V 255V
Nominal discharge current (8/20μs)(L-N/N-PE) In 15kA/20kA 15kA/20kA 15kA/20kA 15kA/20kA 15kA/20kA
Max. discharge current (8/20μs)      (L-N/N-PE) Imax 30kA/40kA 30kA/40kA 30kA/40kA 30kA/40kA 30kA/40kA
Voltage protection level (L-N) Up ≤0.8kV ≤1.3kV ≤1.5kV ≤1.8kV ≤2.0kV
Voltage protection level 5kA (L-N) Up ≤0.6kV ≤1kV ≤1.2kV ≤1.4kV ≤1.6kV
Voltage protection level (N-PE) Up ≤1.5kV ≤1.5kV ≤1.5kV ≤1.5kV ≤1.5kV
Short-circuit withstand capacity Isccr 25kA 25kA 25kA 25kA 25kA
Temporary overvoltage TOV-withstand (L-N) UT 175V/5sec. 335V/5sec. 350V/5sec. 550V/5sec. 580V/5sec.
Temporary overvoltage TOV-safe failure(L-N) UT 250V/120min. 440V/120min. 550V/120min. 660V/120min. 770V/120min.
Temporary overvoltage TOV-withstand(N-PE) UT 1200V/200ms 1200V/200ms 1200V/200ms 1200V/200ms 1200V/200ms
Response time (L-N) tA ≤25ns ≤25ns ≤25ns ≤25ns ≤25ns
Response time (N-PE) tA ≤100ns ≤100ns ≤100ns ≤100ns ≤100ns
Operating temperature range Tu -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red green/red green/red
Cross-section area (Min.) 4mm² 4mm² 4mm² 4mm² 4mm²
Cross-section area (Max.) 35mm² 35mm² 35mm² 35mm² 35mm²
For mounting on 35mm Din rail
Enclosure material Thermoplastic   UL94-V0
Degree of protection IP20 IP20 IP20 IP20 IP20
Order Code B16110 B16122 B16134 B16146 B16158
Order Code (With remote signaling) B16111 B16123 B16135 B16147 B16159

Features:

Britec BR-30FU Series.

Class II

Low residual voltage and quick response

The protection circuitry is based on high energy varistor with thermal disconnection devices.

Up to 30kA class II protection

There is an indicator on the cartridges to signal failure mode.

Protection mode: L1, L2, L3-N, N-PE.

IP20 Protection

Simple DIN rail mounting

Volt-free contacts for remote indication

Operating temperature range: -40°C → +80°C

Conform to IEC61643-11 standards

Consisting of a base part and3 MOV + 1GDT plug-in protection modules.

This is installed in to each electrical switch boards and prevents the spread of surges in the electric systems, protecting the loads.

Application:

BR-30FU 3+1 surge arrester are suitable for lightning and surge protection in AC 50/60Hz

Protection of terminal devices.

Used in AC power line of house, bank, telecom tower and so on.

Used for protection against electrical transients.