Product characteristics:

Specification BR-80 150 1+1 BR-80 275 1+1 BR-80 320 1+1 BR-80 385 1+1
SPD classification according to EN61643-11 Type 2 Type 2 Type 2 Type 2
SPD classification according to IEC61643-11 Class II Class II Class II Class II
Max. continuous operating a.c. voltage(L-N) Uc 150V 275V 320V 385V
Max. continuous operating a.c. voltage(N-PE) Uc 255V 255V 255V 255V
Nominal discharge current (8/20μs) In 40kA 40kA 40kA 40kA
Max. discharge current (8/20μs) Imax 80kA 80kA 80kA 80kA
Voltage protection level (L-N) Up ≤1.0kV ≤1.7kV ≤2.0kV ≤2.3kV
Voltage protection level 5kA (L-N) Up ≤0.5kV ≤0.9kV ≤1.1kV ≤1.3kV
Voltage protection level (N-PE) Up ≤1.5kV ≤1.5kV ≤1.5kV ≤1.5kV
Max. backup fuse 200A gG 200A gG 200A gG 200A gG
Short-circuit withstand capacity Isccr 25kA 25kA 25kA 25kA
Temporary overvoltage TOV-withstand (L-N) UT 175V/5sec. 335V/5sec. 350V/5sec. 550V/5sec.
Temporary overvoltage TOV-safe failure (L-N) UT 250V/120min. 440V/120min. 550V/120min. 660V/120min.
Temporary overvoltage TOV-withstand (N-PE) UT 1200V/200ms 1200V/200ms 1200V/200ms 1200V/200ms
Response time (L-N) tA ≤25ns ≤25ns ≤25ns ≤25ns
Response time (N-PE) tA ≤100ns ≤100ns ≤100ns ≤100ns
Operating temperature range Tu -40℃-80℃ -40℃-80℃ -40℃-80℃ -40℃-80℃
Operating state/fault indication green/red green/red green/red green/red
Cross-section area (Min.) 4mm² 4mm² 4mm² 4mm²
Cross-section area (Max.) 35mm² 35mm² 35mm² 35mm²
For mounting on 35mm Din rail
Enclosure material Thermoplastic   UL94-V0
Degree of protection IP20 IP20 IP20 IP20
Order Code B18360 B18362 B18364 B18366
Order Code (With remote signaling) B18361 B18363 B18365 B18367

Features:

Max. discharge current (8/20 µs), Imax – 80kA.

Mounted: DIN rail.

Low voltage protection level.

Visual indication, green to red, when replacement of the cartridge is required.

Employs metal oxide varistor (MOV) technology.

Thermal isolating arrester disconnector offers a high level of protection against overload.

Compact size, good performance.

Application:

For the protection of low voltage distribution systems against direct lightning strike into the overhead power supply line or external lightning protection system (IEC 62305).

Used in all standard power supply systems, such as distribution box for important electrical equipment of buildings, such as equipment room distribution box.

Generally installed in sub-distribution stations or machine control cabinets.

Used to protect electric system and on-loading electrical apparatus from thunder and instantaneous over-voltage.