Product characteristics:
Specification | BRRJ11L-2L | BRRJ11H-4L | |
Test standards | IEC 61643-21 | ||
Norminal voltage | Un | 110V | 110V |
Max. continuous operating d.c. voltage | Uc | 170V | 170V |
Max. continuous operating a.c. voltage | Uc | 120V | 120V |
Nominal current | IL | 0.5A | 0.5A |
C2 Norminal discharge current (8/20μs) per line | In | 1.5kA | 1.5kA |
Voltage protection level [line-line] | Up | ≤250V | ≤250V |
Voltage protection level [line-PG] | Up | ≤600V | ≤600V |
Response time [line-line] | tA | ≤1ns | ≤1ns |
Response time [line-PG] | tA | ≤100ns | ≤100ns |
Operating temperature range | Tu | -40℃-80℃ | |
Connection input/output | RJ11 socket 2 line | RJ11 socket 4 line | |
Bandwidth | 10Mbps | 30Mbps | |
Insertion Loss | ≤0.3dB | ≤0.3dB | |
Enclosure material | aluminium alloy | ||
Degree of protection | IP20 | IP20 | |
Order Code | D9033 | D9034 |
Features:
Operating voltage: 110V.
Nominal current: 0.5A.
Nominal discharge current: 1.5KA.
Conform to IEC61643-21.
The bandwidth can be 10Mbps、30Mbps.
Low limiting voltage and quick response.
Application:
Protects from voltage spikes and electrical surges, induced by lightning, power line parasites, and other factors.
Protects network or phone lines, modems, fax machines and answering machines against damage from lightning, electrostatic discharge and ground surges.
Protects against the effects of electrostatic discharge, faulty wiring and lightning.
Protect data and communications equipment against AC transients caused by lightning, electrostatic discharge and ground surges that can enter equipment from the signal lines or chassis ground.
Used for modems, telephone lines and answering or fax machines.
Applied to the surge protection for telecommunications, e.g. SPC exchangers, twisted pairs of telephone stations, dial-up lines, DDN special line.
Protection for telephone lines and also for the digital and analogical equipment connected to these lines (fax, modem, etc.).