BR-25M 3P Type 1 25kA Surge Arrester For TN-C

Get A Quote
Description

Product characteristics:

Specification BR-25M 150 3P BR-25M 275 3P BR-25M 320 3P
SPD classification according to EN61643-11 Type 1 + Type 2 +Type 3 Type 1 + Type 2 +Type 3 Type 1 + Type 2 +Type 3
SPD classification according to IEC61643-11 Class I + Class II + Class III Class I + Class II + Class III Class I + Class II + Class III
Nominal operating voltage Un 120V/240V(50/60Hz) 230V/400V(50/60Hz) 250V/440V(50/60Hz)
Max. continuous operating a.c. voltage Uc 150V(50/60Hz) 275V(50/60Hz) 320V(50/60Hz)
Lightning impulse current (10/350μs) Iimp 25kA 25kA 25kA
Total discharge current (10/350μs) Itotal 75kA 75kA 75kA
Nominal discharge current (8/20μs) In 25kA 25kA 25kA
Max. discharge current (8/20μs) Imax 120kA 120kA 120kA
Quantity of electric charge Q 12.5As 12.5As 12.5As
Specific energy W/R 156kJ/Ω 156kJ/Ω 156kJ/Ω
Voltage protection level Up ≤0.8kV ≤1.3kV ≤1.3kV
Short-circuit current rating a.c. Isccr 25kA rms 25kA rms 25kA rms
Max. backup fuse 200A gG 200A gG 200A gG
Temporary overvoltage TOV-withstand UT 175V/5sec. 335V/5sec. 350V/5sec.
Temporary overvoltage TOV-safe failure UT 250V/120min. 440V/120min. 550V/120min.
Leakage current Ipe <2mA <2mA <2mA
Response time tA ≤25ns ≤25ns ≤25ns
Operating temperature range Tu -40℃-80℃ -40℃-80℃ -40℃-80℃
Cross-section area (Min.) 4mm² 4mm² 4mm²
Cross-section area (Max.) 35mm² 35mm² 35mm²
For mounting on 35mm Din rail
Enclosure material Thermoplastic UL94-V0
Degree of protection IP20 IP20 IP20
Order Code B17202 B18133 B17215
Order Code (With remote signaling) B17203 B18134 B17216

Features:

Class B+C surge protector.

This DIN rail mounted surge protectors are easy to install in any standardized distribution pane or control cabinets.

It is equipped with a thermal disconnection device and provides real-time fault indicators thus allowing complete operational safety.

Green/Red window color showing working status, green=normal, red=abnormal.

Continuous working voltage AC UC 150V/275V/320V.

Installation method 35mm wide electrical installation guide rails.

Shell flame retardant.

Built-in thermal failure trip device, safe to use.

Application:

1. General distribution panel in buildings

2. Distribution box with overhead input in buildings

3. Distribution cabinet and distribution box for outdoor high-power equipment.

Installation:

The 25kA first level surge protector shall be installed in a waterproof environment and free from violent vibration.

Ensure that the maximum continuous working voltage of the surge protector meets the actual requirements.

The wire connecting the surge protector should be as short and straight as possible, and the total length of the wire should be controlled within 0.5 meters.

Before powering on the power supply, check whether the cable is securely connected to the wiring terminal and whether the ground is reliable.